Article Open Access1 January 2026

Simultaneous electricity generation and removal of Sars-Cov-2 from wastewater in microbial fuel cell

Order Reprints Cite Share

Sıla ARSLAN, and Tunç ÇATAL

* Author to whom correspondence should be addressed.

Sigma Journal of Engineering and Natural Sciences 2026, Vol. 44, Issue 1, pp. 252-261; doi.org/10.14744/sigma.2026.1981

Download PDF View DOI record

Abstract

In this study, whether wastewater contaminated with SARS-CoV2 virus can be disinfected using microbial fuel cells was modeled using the S1 anchor protein of the virus. The disinfection potential and simultaneous electricity production of wastewater contaminated with SARS-CoV-2 mixed with wastewater using microbial fuel cells, an innovative technology, were investigated. Bioremediation of SARS-CoV-2 contaminated wastewater was modeled using SARS-CoV-2 surface antigen (S1) and studied in microbial fuel cells at different temperatures (30 °C vs. 25 °C). Our results show that microbial fuel cells gradually reduced the SARS-CoV-2 viral concentration from 213 ng/mL, especially at ambient temperature, and simultaneously achieved a power density of 184.19±21.31 mW/m2 at a current density of 0.073±0.029 mA/cm2. The log reduction rates of closed-circuit microbial fuel cells increased steadily from 0.005 to 0.163. In conclusion, microbial fuel cells can be used to simultaneously generate electricity to enable biological treatment of wastewater contaminated by SARS-CoV-2.

Keywords: SARS-CoV-2; Wastewater; Microbial Fuel Cells; S1 Protein; Bioremediation

Introduction

Due to the world’s ever-increasing population and industrialization trend, global water availability and energy consumption have become important topics of discussion. The world population is growing rapidly and is expected to increase by another 21% by 2040. As a result, both the need for clean water and the need for energy are increasing. Fossil fuels are widely used to meet energy needs but are becoming increasingly depleted, so alternative energy sources are needed [1]. Similarly, water scarcity remains a major problem worldwide, and the Earth’s freshwater resources may

decrease by 40% in the next decade [2]. Since organic waste is a viable energy source, wastewater has become a renewable energy source with minimal environmental impact. Microbial fuel cell (MFC) technology, which has versatile features, is a technology on which intensive research has been carried out in recent years, as it enables the production of electricity from organic waste and contributes to the simultaneous production of clean water [3-5]. In microbial fuel cells, microorganisms called exoelectrogens release electrons and protons while breaking down carbon sources in organic waste materials as substrates [6-7-8]. These released electrons are taken by an anode and transferred to

*Corresponding author. *E-mail address: tunc.catal@uskudar.edu.tr This paper was recommended for publication in revised form by Editor-in-Chief Ahmet Selim Dalkilic Published by Yıldız Technical University Press, İstanbul, Turkey © Author. This is an open access article under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Sigma J Eng Nat Sci, Vol. 44, No. 1, pp. 252−261, February, 2026

the cathode through the external circuit. Protons also reach the cathode through the medium solution and react with electrons in the presence of oxygen to form water. Electrical energy is generated as electrons flow through the external circuit. In addition, the breakdown of organic waste and the formation of water by cathodic reaction allows wastewater treatment. Thanks to these versatile features, microbial fuel cells have the potential to support operating costs by being integrated into wastewater treatment plants. By using microbial fuel cells, which are a clean technology, antibiotics, heavy metals, drug metabolites, or various environmental pollutants mixed into wastewater, the ecosystem can be cleaned [9–11]. As a recent contaminant, the detection and disinfection of SARS-CoV-2 viruses, a significant risk, in wastewater has drawn attention to this issue. After infection by the SARS-CoV-2 virus [12], which has affected all humanity and emerged with life-threatening effects in recent years, viral proteins in gastrointestinal epithelial biopsy samples and virus detection in stool samples have been reported [13]. The effects of COVID19 on various patients are still being investigated [14], and using actual data, deterministic COVID-19 models were examined to assess the effects of COVID-19 and dynamic transmission [15]. Viral RNA can be found in the feces of approximately 40% of infected individuals [16]. SARSCoV-2 can be detected in stool samples for longer periods than the virus can be detected in nasal swab samples [16]. Some studies have reported that SARS-CoV-2 survives longer in the urine of infected individuals than in their feces [17]. Accordingly, the SARS-CoV-2 virus in wastewater was investigated [18]. The first detection of SARS-CoV-2 in wastewater was achieved by qRT-PCR testing, isolating it from municipal wastewater in six different cities in the Netherlands. Viral load in wastewater varies by region. In settlements close to sampling sites, the number of viral genomes detected in wastewater has been reported to increase at the regional level due to COVID-19-related hospitalizations [19]. A study by Škulcová et al. [20] reported that the SARS-CoV-2 virus was detected in hospital wastewater, and the relevant virus was detected in the feces of 40% to 89% of COVID-19 patients. Samples taken over sixday periods from a wastewater plant in Australia resulted in two positive results for the presence of SARS-CoV-2 [21]. Additionally, Guerrero-Esteban et al. [22] state that the detection of S1 protein in rivers and wastewater is possible. The immunosensor detects spike protein at the pg/ml level. Miyani et al. [23] investigated the amount of SARSCoV-2 with concentrations of 104–105 genomic copies/L in wastewater. An average of 3.106 genome units per liter were detected in SARS-COV-2 samples from various wastewater treatment plants [24]. Wurtzer et al. [24] reported that the concentration of SARS-CoV-2 increased from 5×104 copies/L to 3×106 genome units per liter in a wastewater treatment plant. In another wastewater treatment plant, SARS-CoV-2 viral RNA N1 and N2 gene regions are quantified in

wastewater solids in water resource recovery facilities [25]. The presence of SARS-CoV-2 in sewers has been identified as an indicator of the potential for the virus to transmit to humans [26]. The Omicron variant was detected in aircraft wastewater [27]. According to a study conducted in 2022, the Omicron variant was found in a wastewater treatment plant [28]. Another study reported an adaptable protocol to monitor SARS-CoV-2 variants in wastewater with high sensitivity and specificity [29]. Various techniques have been proposed to eliminate SARS-CoV-2 from wastewater because it poses a risk to the environment and human health. For example, techniques such as chlorine dioxide, liquid chlorine, sodium hypochlorite, ozone, ultraviolet, and ultrafiltration have been proposed to purify wastewater from SARS-CoV-2 viral load [19]. However, retardation, dispersion, inactivation, and degradation can all have an impact on the destiny of viruses in wastewater. Temperature is the primary factor influencing influencing virus survival [30]. A shorter viral lifespan in the sewage is caused by an increase in the inactivation rate coefficient with temperature [30]. As a disinfection method, microbial fuel cell technology has been proposed to disinfect human urine contaminated with viral load [31]. However, this study is the first in the literature, as there has been no research on SARS-CoV-2 disinfection and simultaneous electricity production using microbial fuel cells. In this regard, this study is novel in that it suggests, for the first time, that SARSCoV2-contaminated wastewater can be disinfected and electricity generated using MFCs. This study used the S1 protein, the protein’s surface antigen of the SARS-CoV-2 virus, to model wastewater contaminated with SARS-CoV-2. The electrical performances of MFCs were evaluated at different temperatures simultaneously with the biological treatment of modeled polluted wastewater. ELISA testing was used to measure the concentration of SARS-CoV-2 viral proteins during operation in MFCs.

Materials And Methods

Materials Inoculation of microbial fuel cells (MFCs) The single-chamber MFC was prepared per the research procedure published in a previous report [3]. Plexiglass, a plastic glass material, was utilized to construct the MFC. The plexi cube had a total volume of 12 mL. The anode’s plexi cover was entirely closed and designed so it would not come into contact with oxygen. This procedure was carried out to prevent oxygen from leaking into the anode region. Carbon cloth was cut to 7 cm2 for it to operate as an anode and a cathode. The anode was made of carbon fabric (Cat. no: 14032102, FuelCells, Texas, USA). The cathode material consisted of coarse carbon cloth (Cat. no: CTO32414, FuelCells, Texas, USA) covered with Nafion

(5%, Sigma–Aldrich, 7 mL per mg of Pt/C catalyst) and platinum (Pt) (20 wt% Pt/C Vulcan XC-72, FuelCell Store, USA) [32,33]. A synthetic wastewater consisting of sodium phosphate buffer (100 mM strength at pH 7.4) and sodium acetate trihydrate (20 mM) (C2H3NaO2.3H2O, VWR Chemicals, Product No: 27652.298, Batch: 15D140018, Geldenaaksebaan, Leuven, Belgium) was prepared [34]. Activated sludge was obtained from a local domestic wastewater treatment plant (Pasakoy, Advanced Biological Wastewater Treatment Plant, Istanbul, Türkiye) [35]. The computer-aided data acquisition system (Keithley KickStart Software, Version 1.9.8.21, Tektronix Company, Beaverton, Oregon, USA) recorded voltage data. The KickStart program was designed to collect data every 11 minutes. MFCs (n=2) operated at 37 °C and 25 °C. Modeling of contaminated wastewater with SARS-CoV-2 SARS-CoV-2 S1 protein (Nepenthe Research Technologies, Ref No: E91011) was used to model the SARS-CoV-2 contaminated wastewater in synthetic wastewater. 23 µL of S1 protein at 1.13 g/mL concentration was kept at -20 °C until use. To detect the wastewater contaminated with SARS-CoV-2, an enzyme-linked immunosorbent assay (ELISA) kit (Nepenthe Research Technologies, 96 tests, Ref No: NE0000211101) research was carried out. The concentration of S1 protein to be used for SARSCoV-2 contaminated wastewater modeling was 213 ng/mL [36]. Operation of MFCs MFCs were operated at 30 °C and 25 °C temperatures using an external resistance of 985Ω in a batch mode. Three and a half hours of operation were completed by sampling 100 µL samples from the reactors at half-hour intervals [31]. All MFCs were examined to monitor the disinfection. The entire operational time was judged to be 40 minutes. Every 10 minutes, 100 µL of the sample was collected. Current (I= V/R) and power (P= I.V.) densities were calculated using voltage (V) data according to Ohm’s law and normalized to the electrode surface area at different external resistances (R) [37]. ELISA Application After the microbial operations were performed, eight different concentrations of S1 standard were prepared by serial dilution technique using the S1 antigen standard solution and blocking solution included in the ELISA kit to determine the concentrations of the samples by creating a standard graph other than the collected samples. ELISA was performed following the kit protocol (Nepenthe Co., Istanbul). Absorbance was measured at 450 nm with a microplate reader (Thermo Scientific, Multiskan Go, Microplate Spectrophotometer). The GraphPad Prism 7.0.0 program was used to calculate the concentration of absorbance data for each sample. The concentration of each sample was determined using the obtained absorbance values. The log reduction was calculated using the pre-operative

Sigma J Eng Nat Sci, Vol. 44, No. 1, pp. 252−261, February, 2026

and post-operative concentrations. The log reduction formula was used as outlined in the study by Pasternak et al. [31]: LR = Log10.(A/B) A equals the antigen concentration of the sample before the operation, and B equals the antigen concentration of the sample after the procedure. Calculation of Statistical Data The t-test p-values were computed using n-Whitney test on the MFCs run using the GraphPad Prism 7.0.0 software. A p-value less than 0.05 indicates that the result iswere determined. In contrast, the t-test reveals whether the findings are substantially different. The time-dependent SARS-CoV-2 concentration and the t-test p-value of the SARS-CoV-2 virus’s log reduction rate was determined as a result.

Results And Discussion

MFC Performances and Effects of SARS-CoV-2 Proteins on Electricity Generation Only 20 mM sodium acetate as the sole carbon source was inoculated into MFC until stable, and consistent voltage data was obtained (for 134 days). During this period, up to 0.394 V of electricity was produced at 30 °C (Fig. 1A). At ambient temperature (25 °C), the outcome of the produced voltage was tracked. The maximum voltage at 25 °C was 0.3810 V (Fig. 1B) at 985 Ohm external resistance. To assess the current and power density, external resistances with varied Ohm values (1204Ω, 985Ω, 646Ω, 325Ω, and 215Ω) were examined. The maximum power density was 145 mW/m2 at the current density level of 0.05 mA/cm2 at 30 °C, where the power density increased when the temperature decreased to 25 °C (210 mW/m2) (Fig. 2B). These results indicate that temperature has an effect on voltage generation and power generation in microbial fuel cells. Synthetic wastewater contaminated with SARSCoV-2 protein was fed to the MFC at 30 °C, and the voltage data was monitored. Under the 30 °C temperature condition, no significant change in voltage production was observed when SARS-CoV-2 protein was introduced into MFCs. Voltage production levels remained at 0.36 V under 30 °C temperature conditions. The maximum voltage produced was 0.36 V. SARS-CoV-2 polluted wastewater modeling at ambient temperature and ambient temperature was performed in the MFC with a 20 mM acetate inoculation solution. However, an instantaneous increase in voltage production was detected when the SARS-CoV-2 viral protein was added to synthetic wastewater at 25 °C (Fig. 3). These findings suggested whether microbial fuel cells could be used as biosensors for the presence of SARS-CoV-2 in wastewaters.

Sigma J Eng Nat Sci, Vol. 44, No. 1, pp. 252−261, February, 2026

Figure 1. Voltage versus time data of MFC with 985 Ω external resistance at controlled temperature (A), Voltage versus time data of MFC with 985 Ω external resistance at ambient temperature.

Figure 3. Voltage during the operation plot of SARS-CoV-2 contaminated wastewater modeling at 30 °C temperature (A) and 25 °C (B). Yellow arrow indicates the addition of SARS-CoV-2 S1 protein.

Removal of SARS-CoV-2 Viral Protein in MFCs Following ELISA, a standard curve was produced based on the absorbance of S1 antigen concentrations at 450 nm (OD450). A total of eight S1 antigen concentrations were used. The created standard curve had an R2 value of 0.9967. Figure 4 shows the standard curve plot of the S1 antigen. At 30 minutes, the concentration of SARS-CoV-2 in the MFC decreased to 47 ng/mL. Under the 30 C temperature condition, S1 protein concentration rapidly decreased (47 ng/L). Concentration levels remained at this level for the 210th minute. However, when the operating temperature was reduced to 25 °C, the decrease in S1 concentration slowed down. At a temperature of 25 °C, S1 concentration reached 180 ng/L. These findings showed that operating temperature is an important parameter in the disinfection of wastewater contaminated with SARS-CoV-2. MFC log reduction rates were computed on an hourly basis. The substantial log reduction rate implied that the SARS-CoV-2 virus was successfully removed. The log reduction rate of

the MFC after half an hour at 30 °C temperature was 1.40. After three and a half hours, it was measured as 0.17. The rate of log reduction steadily reduced (Fig. 5). These results suggest that SARS-CoV-2 viral proteins are removed in MFCs. At 30 minutes, the concentration of SARS-CoV-2 in the closed circuit MFC decreased to 47 ng/mL, while the virus concentration in the abiotic control MFC decreased to 21 ng/mL. At the end of one hour, the SARS-CoV-2 concentration in the closed circuit had risen to 49 ng/mL, whereas the abiotic control had a concentration of 23 ng/mL. After an hour and a half, the SARS-CoV-2 concentration in the closed-circuit MFC sample was 64 nanograms per milliliter. The abiotic control sample obtained simultaneously had a concentration of 36 ng/mL. The fifth sample was obtained from both MFCs after two hours. The concentration of MFC’ in these samples was reduced to 58 ng/mL for the closed circuit MFC’ and 15 ng/mL for the abiotic control MFC. The fifth sample was obtained from both MFCs after

Sigma J Eng Nat Sci, Vol. 44, No. 1, pp. 252−261, February, 2026

two hours. The concentration of MFC’ in these samples was reduced to 58 ng/mL for the closed circuit MFC’ and 15 ng/mL for the abiotic control MFC. The concentration of SARS-CoV-2 contaminated wastewater in the closed circuit MFC was 61 ng/mL after two and a half hours. The concentration of SARS-CoV-2 in the abiotic circuit was 12 ng/mL. Three hours later, the viral concentration in the closed circuit MFC was 65 ng/mL. The appropriate concentration for the abiotic control MFC was 25 ng/mL. The operation of the simulated slater concluded three and a half hours later, with the collection of the final sample. The ultimate sample concentration of MFC in the closed circuit was 59 ng/mL. SARS-CoV-2 was found at a concentration of 43 ng/mL in the final sample of abiotic control MFC (Fig. 6). A novel approach was established for MFCs at ambient temperature based on the operation ELISA findings of MFCs at controlled temperature. The entire operating time in this newly created approach was lowered to forty

Figure 6. Time-dependent concentration graph of MFC at controlled temperature throughout the operation.

Figure 5. Graph of log reduction of MFCs at 30 °C temperature (A). Graph of log reduction of MFCs at 25 °C.

Sigma J Eng Nat Sci, Vol. 44, No. 1, pp. 252−261, February, 2026

minutes, and sample periods were updated to every ten minutes. Given the findings at controlled temperature, it was decided to install an additional circuit (open circuit MFC). The SARS-CoV-2 concentration at which each MFC began functioning was 213 ng/mL. Within the first 10 minutes, the concentration of open-circuit MFC dropped to 65 ng/mL, the closed-circuit open-circuit MFC dropped to 65 ng/mL, the closed-circuit MFC to 213 ng/ mL, and the abiotic control MFC to 133 ng/mL. The SARSCoV-2 concentration of open circuit and abiotic control MFCs rose 20 minutes after the surgery, but the concentration of closed MFCs continued to drop. At 20 minutes, the open circuit MFC concentration was 80 ng/mL. The SARS-CoV-2 concentration in the closed circuit MFC was 206 nanograms per milliliter, whereas it was 138 ng/mL in the abiotic control. Thirty minutes later, the open circuit MFC concentration was determined to be 82 ng/mL. The concentrate circuit closed-circuit MFC steadily decreased, and the SARS-CoV-2 concentration was 178 ng/mL at the end of half an hour. After thirty minutes, the abiotic control MFC had a deadly viral concentration of 108 ng/mL. The concentration of open circuit and abiotic control MFCs continued to grow during the forty-first minute of the operation, whereas it continued to drop in the closed circuit MFCs. In the fortieth minute of the open circuit MFC,

Figure 7. Time-dependent concentration graph of MFC at ambient temperature throughout the operation.

the SARS-CoV-2 concentration climbed to 92 ng/mL. In a closed circuit MFC, the SARS-CoV-2 concentration was determined to be 116 ng/mL. In the last ten minutes, the concentration of SARS-CoV-2 in the abiotic control MFC reached 156 ng/mL. This rate represents an exceptional rise in past operations’ outcomes. At the end of the forty-first minute, the abiotic control MFC’s SARS-CoV-2 concentration was nearly equivalent to the closed circuit MFC, which declined gradually and methodically (Fig. 7). The detection of SARS-CoV-2 in wastewater has been reported previously, and the presence of SARS-CoV-2 in wastewater increases the potential spread. However, the need for SARS-COV-2 removal from wastewater has arisen. Within the scope of the large-scale study by Acosta et al. (2021), wastewater samples were collected twice a week from three different hospitals for four months [38]. It has been reported that the amount of SARS-CoV-2 in wastewater is directly proportional to hospitalizations due to COVID19 cases [38]. The presence and amount of SARS-CoV-2 in the wastewater where the treated water from the wastewater treatment plant mixes into the river, depending on the number of hospitalizations of COVID-19-related cases in the hospital [39], and the SARS-CoV-2 virus was also found in river water and with a high detection frequency. Thus, it has been reported that treating treated wastewater mixed with river water may not be sufficient [39]. The effects of currently used wastewater treatment methods on SAR, such as chlorination of wastewater, ultraviolet (U.V.) irradiation, membrane technology, and advanced oxidation processes the effect of temperature on voltage production in MFCs, were the effect of temperature on voltage production in MFCs was the effect of temperature on voltage production in MFCs was the effect of temperature on voltage production in MFCs was reported and showed that it has an impact on power production [40]. Pasternak et al. [31], a deadly pathogen and biological contaminant, succeeded in separating the hepatitis B virus from human urine and generating electricity using MFCs [31]. Enough removal of hepatitis B viruses by microbial fuel cells was reported to reduce the risk of viral spread. However, they stated that they needed to apply the method they developed to different kinds of viruses to make the results more explainable. The log reduction rate calculated by Pasternak et al. [31] for the surface antigen started from almost 5 for the closed

Table 1. Comparison of MFC performances for disinfection of various contaminants Disinfected material

Sigma J Eng Nat Sci, Vol. 44, No. 1, pp. 252−261, February, 2026

Table 2. The statistical significance of the difference between time-dependent concentration values of S1 antigen of MFCs (*). The statistical significance of the difference between SARS-COV-2 log reduction values of MFCs (**) Controlled Temp.

circuit MFC. The log reduction rates of hepatitis B virus surface antigen gradually decreased for both MFCs [31]. In our study, the first log reduction rate of the closed circuit MFC in a temperature environment of 30±2°C was 1.40. While the initial SARS-CoV-2 log reduction rate calculated for the closed circuit MFC at room temperature was 0.005, this rate increased gradually throughout the operation period. It reached 0.163 at the end of forty minutes. The difference in log reduction between the study of Pasternak et al. [31] and our study at room temperature is thought to be due to the different biofilm structures of MFCs or the difference in the viruses used [31–41]. These results suggest that external factors such as temperature and MFC configuration may affect the disinfection of SARS-CoV-2, where simultaneous electricity can be generated. The t-test p-value of the closed circuit MFC and abiotic control reactor in a controlled temperature environment was 0.007, and the time-dependent SARS-CoV-2 concentration data of the two bioreactors differed considerably. Three distinct MFC time-dependent SARS-CoV-2 concentration values at ambient temperature were statistically compared. The t-test p-value for closed-circuit MFC and open-circuit MFC was 0.01, suggesting that they varied substantially. Again, at ambient temperature, the t-test p-value of the closed circuit MFC and abiotic control bioreactors was 0.05, and the time-dependent concentration values were not substantially different. Finally, the t-test p-value of 0.22 showed that the time-dependent SARS-CoV-2 concentration data from open MFC and abiotic control bioreactor were not significantly different (Table 1). The t-test p-value for SARS-CoV-2 log reduction values of the closed circuit MFC and abiotic control bioreactors in a controlled temperature environment was 0.0012, showing a significant difference between the two bioreactors. In an ambient temperature setting, the t-test p-value findings of the SARS-CoV-2 log reduction values of three distinct MFCs were comp circuit circuit open-circuit MFC and closed-circuit MFC was 0.03, and the log reduction difference was significant. Closed circuit MFC and abiotic control had a t-test p-value of 0.03, indicating a significant difference between these two bioreactors. Lastly, at ambient temperature, the t-test p-value of the open circuit MFC

and abiotic control was determined to be 0.03. This finding indicates that the log reduction value of the SARS-CoV-2 virus differs significantly across the two MFCs (Table 1). Not only viruses but also other contaminants can be treated in MFCs. The efficiency and efficacy of heavy metal removal from wastewater are anticipated to be substantially improved by current research endeavors and advancements in MFC technology [42]. It is highly conceivable that autonomous wastewater treatment plants and MFCs—capable of remotely detecting —will be used in the future [43]. For this purpose, MFC technology can support the development of biosensors that can perform target-oriented detection. Our findings on eliminating SARS-CoV-2 from wastewater represent a substantial improvement in public health protection and environmental sustainability. By incorporating MFCs into wastewater treatment facilities, we can improve disinfection while decreasing virus loads and creating renewable energy. These findings have far-reaching ramifications, advising policymakers about new policies prioritizing pathogen elimination in wastewater management. Furthermore, MFC technology may be used to remove different types of organisms.

Conclusion

In conclusion, the concentration of SARS-CoV-2 protein declined progressively over the operation duration of the microbial fuel cells, which were operated in a 25 °C temperature environment. It did not rise during the operating period of the other examined reactors. Simultaneously, the log decrease rate progressively and steadily increased. In addition to all of this, the power generation efficiency was fairly great. As a result, it was determined that microbial fuel cells, running at a temperature of 25 °C ambient temperature, executed the treatment of SARS-CoV-2 contaminated wastewater in a steady and circulatory manner, the bio removal of SARS-CoV-2 was accomplished, and there was considerable power production. Various parameters are needed for our promising work to be developed and extensively used. It is hoped that researching how diseases are removed at the molecular level may pave the way for more effective removal and eradication of additional pathogens. This study gives information on the real investigation of

Sigma J Eng Nat Sci, Vol. 44, No. 1, pp. 252−261, February, 2026

SARS-CoV-2 polluted wastewater in advance. Furthermore, bioremediation of SARS-CoV-2 polluted wastewater using microbial fuel cells is expected to limit the production of new variants. Our findings suggest that novel microbial biosensors could be developed to detect the SARS-CoV-2 virus in wastewater.

Data Availability Statement

The authors confirm that the data that supports the findings of this study are available within the article. Raw data that support the finding of this study are available from the corresponding author, upon reasonable request.

Conflict Of Interest

The author declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.

Ethics

There are no ethical issues with the publication of this manuscript.

Statement On The Use Of Artificial Intelligence

Artificial intelligence was not used in the preparation of the article.

References

  1. Naseer MN, Zaidi AA, Khan H, Kumar S, Owais P, Hassani MK. Numerical study and dynamics MT, Jaafar J, et al. Mapping the field of microbial fuel analysis of diabetes mellitus with co-infection of cell: A quantitative literature review (1970-2020). COVID-19 virus by using fractal fractional opera- Energy Rep 2021;4126−4138. [CrossRef] tor. Scientific Reports 2024;14:16489. [CrossRef]
  2. Gupta S, Srivastava P, Patil SA, Yadav AK. A com- prehensive review on emerging constructed wetland AH. Stability and complex dynamical analysis of coupled microbial fuel cell technology: Potential COVID-19 epidemic model with non-singular applications and challenges. Bioresource Technol kernel of Mittag-Leffler law. J Appl Mat Comput 2021;124376. [CrossRef] 2024;70:3441–3476. [CrossRef]
  3. Catal T, Liu H, Kilinc B, Yilancioglu K. Extracellular polymeric substances in electroactive biofilms play a BBO, Schapendonk CME, Nieuwenhuijse D, et al. crucial role in improving the efficiency of microbial Monitoring SARS-CoV-2 Circulation and Diversity fuel and electrolysis cells. Appl Microbiol 2024;77. through Community Wastewater Sequencing, [CrossRef] the Netherlands and Belgium. Emerg Infect Dis
  4. Durna Piskin E, Genc N. Microbial fuel cells 2021;27:1405–1415. [CrossRef] in electricity generation with waste treatment: [17] Zamhuri SA, Soon CF, Nordin AN, Rahim RA, Alternative electron acceptors. Sigma J Eng Nat Sci Sultana N, Khan MA, et al. A review on the con- 2024;42:273−288. [CrossRef] tamination of SARS-CoV-2 in water bodies:
  5. Sukkasem C. Exploring biofilm-forming bacteria for Transmission route, virus recovery and recent bio- integration into BioCircuit wastewater treatment. sensor detection techniques. Sens Bio-Sens Res Eur Chem Biotechnol J 2024;2:39–52. [CrossRef] 2022;100482. [CrossRef] 260 Sigma J Eng Nat Sci, Vol. 44, No. 1, pp. 252−261, February, 2026
  6. Reynolds LJ, Gonzalez G, Sala-Comorera L, Martin NA, Byrne A, Fennema S, et al. SARS-CoV-2 vari- SJD, Verhaegen B, Lesenfants M, Janssens R, et ant trends in Ireland: Wastewater-based epidemi- al. Development of a reverse transcriptase digital ology and clinical surveillance. Sci Total Environ droplet polymerase chain reaction-based approach 2022;155828. [CrossRef] for SARS-CoV-2 variant surveillance in waste-
  7. Zahmatkesh S, Amesho KT, Sillanpää M. A crit- water. Water Environment research: a research ical review on diverse technologies for advanced publication of the Water Environment Federation wastewater treatment during SARS-CoV-2 pan- 2024;96:e10999. [CrossRef] demic: What do we know? J Hazardous Mater Adv [30] Kallem P, Hegab H, Alsafar H, Hasan SW, Banat F. 2022;7:100121. [CrossRef] SARS-CoV-2 detection and inactivation in water
  8. Škulcová AB, Tamášová K, Staňová AV, Bírošová and wastewater: review on analytical methods, L, Krahulcová M, Gál M, et al. Effervescent fer- limitations and future research recommendations. rate(VI)-based tablets as an effective means for Emerg Microbes Infect 2023;12:2222850. [CrossRef] removal SARS-CoV-2 RNA, pharmaceuticals and [31] Pasternak G, Greenman J, Ieropoulos I. Removal of resistant bacteria from wastewater. J Water Proc Eng Hepatitis B virus surface HBsAg and core HBcAg 2021;43:102223. [CrossRef] antigens using microbial fuel cells producing elec-
  9. Ahmed W, Angel N, Edson J, Bibby K, Bivins A, tricity from human urine. Sci Rep 2019;9:11787. O’Brien JW, et al. First confirmed detection of [CrossRef] SARS-CoV-2 in untreated wastewater in Australia: [32] Cheng S, Liu H, Logan BE. Increased performance A proof of concept for the wastewater surveillance of single-chamber microbial fuel cells using an of COVID-19 in the community. Sci Total Environ improved cathode structure. Electrochem Commun 2020;728:138764. [CrossRef] 2006;8:489−494. [CrossRef]
  10. Guerrero-Esteban T, Gutiérrez-Sánchez C, Villa- Manso AM, Revenga-Parra M, Pariente F, Lorenzo tion from twelve monosaccharides using micro- E. Sensitive SARS-CoV-2 detection in waste- bial fuel cells. J Power Sources 2008;175:196−200. waters using a carbon nanodot-amplified elec- [CrossRef] trochemiluminescence immunosensor. Talanta [34] Lovley DR, Phillips EP. Novel mode of microbial 2022;247:123543. [CrossRef] energy metabolism: organic carbon oxidation cou-
  11. Miyani B, Fonoll X, Nortan F, Mehrotra A, pled to dissimilatory reduction of iron or manga- Xagoraraki I. SARS-CoV-2 in Detroit Wastewater. J nese. App Environ Microbiol 1988;54:1472−1480. Environ Manage 2020;146:06020004. [CrossRef] [CrossRef]
  12. Wurtzer S, Marechal V, Mouchel JM, Maday Y, Teyssou R, Richard E, et al. Evaluation of lockdown genesis for hydrogen production in single-chamber effect on SARS-CoV-2 dynamics through viral microbial electrolysis cells using various antibiotics. genome quantification in waste water. Euro Surveill Bioresour Technol 2015;187:77−83. [CrossRef] 2020;25:pii=2000776. [CrossRef] [36] Bar-Or I, Indenbaum V, Weil M, Elul M, Levi
  13. D’Aoust PM, Mercier E, Montpetit D, Jia JJ, N, Aguvaev I, et al. National Scale Real-Time Alexandrov I, Neault N, et al. Quantitative analy- Surveillance of SARS-CoV-2 Variants Dynamics sis of SARS-CoV-2 RNA from wastewater solids in by Wastewater Monitoring in Israel. Viruses communities with low COVID-19 incidence and 2022;14:1229. [CrossRef] prevalence. Water Res 2021;188:116560. [CrossRef] [37] Sonmez E, Avci B, Mohamed N, Bermek H.
  14. Al-Gheethi A, Al-Sahari M, Malek MA, Noman E, Investigation of performance losses in microbial fuel Al-Maqtari Q, Mohamed R, et al. Disinfection Methods cells with low platinum loadings on air-cathodes. and Survival of SARS-CoV-2 in the Environment and Eur Chem Biotechnol J 2024;1:11–26. [CrossRef] Contaminated Materials: A Bibliometric Analysis. [38] Acosta N, Bautista MA, Hollman J, McCalder J, Sustainabilty 2020;12:7378. [CrossRef] Beaudet AB, Man L, et al. A multicenter study
  15. Ahmed W, Bivins A, Smith WJM, Metcalfe S, investigating SARS-CoV-2 in tertiary-care hospital Stephens M, Jennison AV, et al. Detection of the wastewater. viral burden correlates with increas- Omicron (B.1.1.529) variant of SARS-CoV-2 in air- ing hospitalized cases as well as hospital-associ- craft wastewater. Sci Total Environ 2022;820:153171. ated transmissions and outbreaks. Water Research [CrossRef] 2021;201:117369. [CrossRef]
  16. Wilhelm A, Schoth J, Meinert-Berning C, Agrawal S, Bastian D, Orschler L, et al. Wastewater surveil- SP, Shakya BM, et al. Detection of SARS-CoV-2 lance allows early detection of SARS-CoV-2 omi- RNA in wastewater, river water, and hospital waste- cron in North Rhine-Westphalia, Germany. Sci water of Nepal. Sci Total Environ 2022;824:153816. Total Environ 2022;846:157375. [CrossRef] [CrossRef] Sigma J Eng Nat Sci, Vol. 44, No. 1, pp. 252−261, February, 2026 261
  17. Catal T, Kavanagh P, O’Flaherty V, Leech D. Generation of electricity in microbial fuel cells Microbial fuel cells: A potent and sustainable solu- at sub-ambient temperatures. J Power Sour 2011;196:2676−2681. [CrossRef] tion for heavy metal removal. Eur Chem Biotechnol
  18. Emalya N, Tarmizi S, Munawar E, Fellner J, Yunardi. J 2025;1:45–69. [CrossRef] Coupling electrochemical energy generation with [43] Catal T, Liu H. Microbial fuel cell technology: leachate bioremediation in sediment microbial fuel cell reactors. Case Stud Chem Environ Eng Novelties for a clean future. Eur Chem Biotechnol J 2024;10:100896. [CrossRef] 2025;1:1–20. [CrossRef]

Share and Cite

ARSLAN, S.; ÇATAL, T. Simultaneous electricity generation and removal of Sars-Cov-2 from wastewater in microbial fuel cell. Sigma Journal of Engineering and Natural Sciences 2026, Vol. 44, pp. 252-261. https://doi.org/10.14744/sigma.2026.1981

Export:

Related Articles

Network-based community detection of early-stage COVID-19 pandemic based on the international geograDuygu BAĞCI DAŞ, Zerrin IŞIK, 1 January 2023Recent advances in health biotechnology during pandemicSelcen ARI YUKA et al. (SABIOTEK Collaboration), 1 January 2023Bioinformatic analysis reveals that some bacteria may aid SARSCoV-2 spread and entry into host cellsEmre AKTAŞ, Safiye Elif KORCAN et al., 1 January 2021Separation of coii and sevi from a metal and glass industry wastes using graphene oxide-mangane oxidSevil AKÇAĞLAR, 1 January 2020
Publication History
Published1 January 2026
Versionv1
AccessOpen Access
10.14744/sigma.2026.1981
Article Figures (7)
Figure 1Figure 2Figure 3Figure 4Figure 5Figure 6Figure 7
Related Articles
Network-based community detection of early-stage COVID-19 pandemic based on the international geograDuygu BAĞCI DAŞ, Zerrin IŞIKSigma Journal of Engineering and Natural Sciences, 1 January 2023Recent advances in health biotechnology during pandemicSelcen ARI YUKA et al. (SABIOTEK Collaboration)Sigma Journal of Engineering and Natural Sciences, 1 January 2023Bioinformatic analysis reveals that some bacteria may aid SARSCoV-2 spread and entry into host cellsEmre AKTAŞ, Safiye Elif KORCAN et al.Sigma Journal of Engineering and Natural Sciences, 1 January 2021
Sigma Journal of Engineering and Natural Sciences coverSigma Journal of Engineering and Natural Sciences Download PDF

Subscribe to YTUP

Stay connected and receive the latest research updates directly in your inbox.

YTUP — Yıldız Technical University Publishing

Advancing knowledge and fostering innovation through high-quality, peer-reviewed academic publications.

About YTU

Discover

  • ›Articles
  • ›Journals
  • ›Research Topics
  • ›Open Access Policy

Guidelines

  • ›Author guidelines
  • ›Services for authors
  • ›Policies and publication ethics
  • ›Editor guidelines
  • ›Fee policy

Explore

  • ›Articles
  • ›Research Topics
  • ›Journals
  • ›How we publish

Support

  • ›Help center
  • ›Emails and alerts
  • ›Contact us
  • ›Submit
  • ›Career opportunities
YTU Logo

© 2026 Yıldız Technical University (Istanbul, Turkey)

Terms and ConditionsTerms of UsePrivacy PolicyPrivacy SettingsDisclaimer
Like this platform? Join our teamHave feedback or questions?
Supervisor