YTUP
Journals
About
Services
Guides
Sign InSubmit Article
HomeJournalsJournal of Sustainable Construction Materials and Technologies10.47481/jscmt.1607472
JoJournal of Sustainable Construction Materials and Technologies
Get Alerted Download PDF
AbstractKeywords1. Introduction2. Modeling And Analysis Of Structures3. Results And Discussions2. The maximum displacement of the soft storey building4. ConclusionsEthicsData Availability StatementFinancial DisclosureReferencesShare and CiteRelated Articles
Article Open Access1 January 2024

Moderating the Soft Storey Impact in Multi-Storey Buildings A Comparative Seismic Investigation

Order Reprints Cite Share

Shabla K1, K.i. Praseeda1, and Chıtaranjan Pany2

1Department of Civil Engineering, NSS College of Engineering Palakkad
2Vikram Sarabhai Space Centre, Structural Engineering

Journal of Sustainable Construction Materials and Technologies 2024, Vol. 9, Issue 4, pp. 4; doi.org/10.47481/jscmt.1607472

Download PDF View DOI record

Abstract

A storey with lateral stiffness less than 70% of the storey above or less than 80% of the average stiffness of the three storeys above is considered a soft storey. Ground-floor open-air buildings are frequently used for parking, particularly in metropolitan settings with considerable space limits. Soft-story buildings with irregular stiffness tend to collapse more than conventional buildings. The study's main goal was to understand better the soft storey effect in multi-storey structures and how to mitigate it using strategies such as adding shear walls, bracings, viscous dampers, and stiffer columns. A G+14 storey building finite element model (FEM) has been established via ETABS software and performed Response Spectrum Analysis at three seismic zones-III, IV and V. To determine the best method for reducing the soft storey effect in buildings, an analysis is conducted taking into account many parameters, including storey shear, stiffness, storey drift, and storey displacement for the entire structure, as well as the responses at the soft storey level for different configurations. According to the findings, adding a shear wall to a soft-storey building increases storey shear while reducing maximum displacement and storey drift. The first floor of the structure (soft storey) exhibits the most significant reduction in displacement (79.29%) and storey drift (79.3%) when shear walls are incorporated at the corners. There is also a 33.11% increase in base shear at the first story level, and the structure's stiffness increases by 6.5 times compared to a soft storey building. Adding a shear wall reduces the soft storey building's maximum displacement and storey drift by 25.27% and 59.28%, respectively. The soft storey building's maximum storey shear rises by 33.38%. Regarding seismic performance, a soft-storey building with a shear wall performs better than other soft-storey mitigation techniques.

Keywords: Bracings; response spectrum analysis; shear wall; soft storey; stiffer columns; viscous damper

1. Introduction

Parking is needed, particularly in cities with severe space restrictions. Under these circumstances, buildings' ground floors remain open without the addition of any infill walls to make room for parking. Buildings get stiffness irregularities as a result. The ground floor displacement

moves significantly when subjected to seismic force, while the upper stories, which move as one unit, move far less. As seen in Figure 1, this produces a weak point and causes the building to fall entirely [1]. The research aims to study the soft storey effect in multi-storey structures and find ways to address it by using stiffer columns, shear walls, bracings, and viscous dampers, among other methods.

*Corresponding author. *E-mail address: shabla1999@gmail.com Published by Yıldız Technical University Press, İstanbul, Türkiye This is an open access article under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

J Sustain Const Mater Technol, Vol. 9, Issue. 4, pp. 355–364, December 2024

Figure 1. Soft storey building failure during Gujarat Earthquake (2001) in India [1]. Seismic retrofitting has now become a critical problem. Retrofitting aims to improve the structure's strength, resistivity, and lifespan. Recent earthquakes in different regions have emphasized the urgency of repairing inadequate seismic structures. The review paper [2] summarized the solution to seismic strengthening. Seismic study of multi storey building with and without floating column carried out and its effects presented [3]. The wall piers were modeled using a multi-layer shell element based on the composite strength of materials, which was divided into one or more orthotropic reinforcement layers and several concrete layers with equivalent thickness according to the reinforcement situation and actual component size [4]. Shear walls withstand lateral forces like wind and seismic activity and thereby increase lateral stability and safety of the building, usually constructed from materials like reinforced concrete or steel. Shear walls enhance the stiffness of the structure and thereby decrease the displacement of the structure. The incorporation of shear wall at corners increased storey stiffness and reduced displacement, thereby effectively transforming the soft storey into a standard structure and enhancing overall structural stability [5]. Bracing systems, such as V, cross, and diagonal bracing, help to mitigate soft storey effects in multi-storey buildings, distribute seismic forces uniformly to the structure and enhance structural stability. The optimum location of bracings in a building is at the corners. Strengthening ground storey columns effectively addresses soft storey vulnerabilities by increasing stiffness and load-bearing capacity, reducing the risk of structural damage during seismic events. Viscous dampers, strategically placed within the soft storey, dissipate energy and minimize lateral movement, providing cost-effective retrofitting solutions that enhance resilience of building to seismic forces. Strengthening the columns in the ground storey of building is a highly effective strategy for addressing the soft storey issue in open ground storey structures [6-14]. Kannan (2023) evaluated the effects of a soft storey for frames with different column shapes in different earthquake zones and locations along the soft storey's axis, from the first to the top level. Analyses using X bracings and shear walls were conducted. According to findings, shear walls can be employed in seismic danger zones because

(c) Figure 2. Comparison of displacement of (a) soft storey building, (b) soft storey building with shear wall and (c) soft storey building with bracings. they lessen lateral displacement and storey drift. For low seismic zones, steel bracing is advised [15]. The impact of a soft storey and its placement on the seismic behavior of a supporting building and non-structural components was investigated by Pesaralanka et al. [16] in 2023. The models' bottom (ground), middle, and top storey levels retain the soft narrative's placement. According to the study, there is a significant vertical stiffness irregularity in the bottom soft storey, which suggests that the seismic performance of ground-level open-storied buildings has to be investigated [16]. To lessen the effect of soft storeys on the dynamic performance of the structure, Chanumolu and

J Sustain Const Mater Technol, Vol. 9, Issue. 4, pp. 355–364, December 2024

Table 1. Model description Description No. of stories Storey height Type of soil Grade of steel Grade of concrete Modulus of elasticity of concrete Modulus of elasticity of steel Live load Floor finish Importance factor Response reduction factor Seismic zone Wind Speed Terrain category Column size Beam size Plinth beam size Thickness of Slab Thickness of brick wall Thickness of shear wall Steel section Thickness of stiffer column Viscous damper

3.5. kN/m2

1 kN/m2 1 3 III, IV and V 50 m/s 3 600 mm x 600 mm 300 mm x 500 mm 400 mm x 600 mm 150 mm 230 mm 230 mm ISMB 350 600 mm x 800 mm FVD500

Anthugari (2020) arranged gap components at beam-column joints to act as a spring in either or both of the beam and column. When compared to the standard models, this aids in lowering storey displacements, inter-storey drift ratios, over-turning moments, and an increase in storey stiffness [17]. Comparative seismic response analysis of the two multi-storey reinforced concrete 3D frames under seismic loads, with and without base isolation, was carried out by Qambrani and Mirza (2023). The analysis findings demonstrate how well base isolators work in Balochistan's high-seismic-risk Zone 4 to lessen displacements, drifts, and shear in multistorey buildings. The building time period, stiffness, and energy dissipation were all successfully extended by LRB isolators [18]. The strategies above contribute to the mitigation of soft storey vulnerabilities in diverse ways, and it is necessary to determine the most effective technique for seismic retrofitting structures. This study aims to evaluate different soft storey mitigation strategies, such as stiffer columns, bracings, dampers, and shear walls, to identify the most efficient method for reducing the soft storey effect in multi-storey buildings. The study technique entails a detailed analysis utilizing ETABS software to model the behavior of structural components in connection with the soft storey effect in multi-storey structures.

2. Modeling And Analysis Of Structures

Modeling of a G+6-storey building with a symmetrical floor plan, as presented in [6], was done using ETABS software. Analyzes of a soft-storey bare-frame building with

Figure 3. (a) Building with ground open storey, Soft storey building with (b) cross bracings, (c) diagonal bracings, (d) V bracings, (e) viscous damper, (f) shear wall, (g) stiffer columns.

J Sustain Const Mater Technol, Vol. 9, Issue. 4, pp. 355–364, December 2024

Figure 4. Spectra for response spectrum method [19]. cross bracings and a shear wall were performed, compared with the results in the literature, validating the analytical procedure. The comparison between results obtained from ETABS for the present study and the literature is shown in Figure 2. The G+14-storey building is modeled as a bare-frame, soft-storey building using ETABS software with cross bracings, diagonal bracings, V-shaped bracings, viscous dampers, shear wall and stiffer columns using ETABS 18.0.2 standard. The beam modeling of infill walls is done using the corresponding method of diagonal bracings given in Part 1 of IS1893 2016. The dimensions of buildings and parts are described in Table 1. Models of bare frame models, soft floor buildings with cross bracings, diagonal bracings, V- bracings, viscous dampers modeled with ETABS 18.0.2 software, shear wall, and stiffer columns are shown in Figure 3a–g. A ground-floor open-storey building is modeled by keeping the ground floor unoccupied and adding infill walls to the higher floors, as seen in Figure 3a. According to IS1893 2016 Part 1, the masonry infill wall of the building is modeled using an equivalent diagonal strut approach. 𝑊𝑑𝑠=0.175(𝛼ℎ)−0.4𝐿𝑑𝑠 where αh=h ∜(Em t sin(2θ))⁄(4 Ef Ic h) ℎ=Height of infill panes Ef=Expected elastic modulus of frame material Em= Expected elastic modulus of infill material, Em=550 x fm where fm is the compressive strength of masonry prism (in MPa) obtained as per IS 1095 or given by expression: fm=0.433x𝑓𝑏0.64𝑥𝑓𝑚𝑜0.36 where fb is the compressive strength of brick in MPa and fmo is the compressive strength of mortar in MPa Ic=Moment of inertia of column 𝐿𝑑𝑠=Diagonal length of infill panel t=Thickness of infill panel and equivalent strut 𝜃=Angle whose tangent is the infill height-to-length aspect ratio 𝐿=Length of infill wall By substituting these values, 𝛼ℎ=2.0038749 and 𝑊𝑑𝑠=583 mm Response Spectrum Analysis in ETABS software analyzes various models, such as bare frames, soft storey buildings with cross bracings, diagonal bracings, V bracings, viscous dampers, shear walls, and stiffer columns.

Figure 5. Comparison of displacement in first storey level for different models. (a)

Figure 6. Comparison of different models in (a) seismic zoneIII, (b) seismic zoneIV and (c) seismic zone V.

J Sustain Const Mater Technol, Vol. 9, Issue. 4, pp. 355–364, December 2024

Table 2. Comparison of displacement at first storey level obtained for different models Models

Table 3. Comparison of maximum displacement obtained for different models Models

Table 4. Comparison of storey drift at first storey level obtained for different models Model

The spectra for the response spectrum method are shown in Figure 4. The system's maximum acceleration, velocity, and displacement values in response to time-dependent dynamic excitation are displayed graphically in the response spectrum. Maximum displacement, storey drift, storey shear, and stiffness are the basis for the analysis. The response of the entire structure and the reaction on the first floor are considered. While storey drift is the relative horizontal displacement between two neighboring floors or storeys during an earthquake, maximum displacement is the most prominent horizontal movement a specific storey within the structure experiences. In a structure, storey shear is the lateral force that external sources, such as lateral loads, act on a particular level or storey. The resistance to deformation under external loads is measured by stiffness.

3. Results And Discussions

Comparisons are made between the displacement, storey drift, stiffness, and storey shear results for several models in seismic zones III, IV, and V.

3.1. Storey Displacement

Figure 5 compares the displacement at the first storey level for various models. Figures 6a–c show the results for the maximum displacement in the different models for seismic zones III, IV, and V, respectively. Tables 2 and 3 compare displacement at the soft storey level and the maximum displacement of various models, respectively, about the soft storey building. It is noted that, as illustrated in Figure 5, the soft storey building with shear wall experiences the least displacement at, while the bare soft storey building experiences the high-

J Sustain Const Mater Technol, Vol. 9, Issue. 4, pp. 355–364, December 2024

Figure 7. Comparison of storey drift in first storey level for different models. est displacement. When a soft storey structure incorporates a shear wall, viscous damper, cross bracings, V bracings, stiffer columns, and diagonal bracing, the first storey displacement appears to reduce by 79.29%, 75.18%, 41.4%, 33.5%, 29.11%, and 25.8%, respectively, as shown in Table

2. The maximum displacement of the soft storey building

decreases when shear walls, cross bracings, V bracings, stiffer columns, diagonal bracings, viscous dampers, and stiffer columns are incorporated, by amounts of 25.27%, 4.05%, 3.12%, 3.04%, 1.95%, and 1.95%, respectively, as shown in Table 3. It is also clear from Figure 6 that, as one moves into greater seismic zones, lateral displacement increases because of the stronger seismic action. Shear walls, bracings, and stiffer columns all contribute to increased stiffness, which lessens lateral sway and displacement. The addition of a damper causes energy to be absorbed and dispersed, which lowers lateral movement.

3.2. Storey Drift

Figure 7 compares the storey drift at the first storey level for several models. Figure 8a–c show the maximum storey drift for various models for seismic zones III, IV, and V, respectively. Tables 4 and 5 present a comparison of storey drift at the soft storey level and the maximum displacement of various models, respectively, in relation to the soft storey building. The first floor storey drift is reduced by 79.3%, 79.25%, 42.99%, 34.64%, 29.46%, and 27.52 when shear wall, viscous damper, cross bracings, V-braces, stiffer columns and diagonals bracings respectively as shown in Figure 7 (Table 4). Figure 8–c it is evident that the maximum storey drift of the soft floor building is reduced by 59.28%, 40.85%, 40.3%, 34.52%, 29.29% and 27.37% when the shear wall, cross bracings, viscous dampers and V bracings, stiffer columns and diagonal braces are added, as shown in Table 5. Reduction of storey drift through soft storey mitigation measures due to reduced lateral movement.

3.3. Storey Shear

Variation of storey shear for different models in first storey level is shown in Figure 9. Storey shear for different models for seismic zone III, IV and V are illustrated in Figure 10a–c respectively. Tables 6 and 7 present a comparison

Figure 8. Comparison of storey drift for different models in (a) seismic zone III, (b) seismic zone IV and (c) seismic zone V. of storey shear at the soft storey level and the maximum displacement of various models, respectively, in relation to the soft storey building. Storey shear is highest for soft storey given with shear wall. Figure 9 demonstrates that base shear (or storey shear in first floor level) increments by 33.11%, 2.92%, 2.58%, 2.39% and 2.05%by the incorporation of shear wall, cross bracings, stiffer columns,V bracings and diagonal bracings separately as shown in Table 6. It is additionally apparent that base shear diminishes by 89.7% with the consolidation of viscos damper due to the adaptability afforded by damper which makes the building less stiffer. From Figure 10 a-c, it is appeared that maximum storey shear of the soft storey building increases by 33.38%, 2.92%,2.76%,2.4%, 2.08% and 2.07% with the addition of shear wall, cross bracings, stiffer columns, V bracings, viscos damper and diagonal bracings,

J Sustain Const Mater Technol, Vol. 9, Issue. 4, pp. 355–364, December 2024

Table 5. Comparison of maximum soft drift obtained for different models Models

Table 6. Comparison of base shear obtained for different models Model

Table 7. Comparison of maximum storey shear obtained for different models Models

as depicted in Table 7. This trend is due to enhancement of stiffness which improves the effective distribution of lateral force within the structure and hence storey shear at each level increases.

3.4. Storey Stiffness

Variation of stiffness for different models in first storey level in shown in Figure 11. Stiffness for different models for seismic zone III, IV and V are illustrated in Figure 12–c respectively. Table 8 present a comparison of stiffness at the soft storey level of various models, respectively, in relation to the soft storey building. Since stiffness is not zone-specific, the stiffness of the models is constant throughout the three zones. It is evident from Figure 11 that adding a shear wall, cross bracings, V bracings, stiffer columns, and diagonal bracings increases stiffness at the first storey level by 549.12% (6.5 times),

Figure 9. Comparison of storey shear in first storey level for different models. 84.27%, 58.057%, 46.09%, and 45.06%, respectively, as shown in Table 8. This is because these structural components were able to distribute the load effectively. Because

J Sustain Const Mater Technol, Vol. 9, Issue. 4, pp. 355–364, December 2024

Table 8. Comparison of stiffness obtained for different models Stiffness (kN/m)

Figure 11. Comparison of stiffness in first storey level for different models. (b)

of the flexibility that the viscous damper adds to the level, the structure's stiffness at the first storey level decreases by a factor of 27.19% when incorporated. Three seismic zones' worth of variations in stiffness for various models are depicted in Figures 12a–c. The percentage increase in the overall stiffness of soft storey buildings resulting from including viscous damper, cross bracings, stiffer columns, and the shear wall is 16.05%, 7.56%, and 1.18%. Including V and diagonal bracings reduces stiffness by 0.14% and 0.05%, respectively.

4. Conclusions

Figure 10. Comparison of storey shear for different models in (a) seismic zone III, (b) seismic zoneIV and (c) seismic zone V.

Because of their irregular stiffness, soft-storey buildings are more likely to collapse after an earthquake. Therefore, buildings must minimize the impact of their soft stories. Comparative seismic analysis is researched to lessen the soft storey impact on structures. Shear walls, cross bracings, diagonal bracings, V bracings, stiffer columns, and viscous dampers approaches are used in the present study to know their effect. The following are the study's main conclusions: • The addition of different soft storey mitigation techniques improved the seismic performance of the soft storey building. • The structure's first floor exhibits the most significant reduction in displacement (79.29%) and storey drift (79.3%) when shear walls are incorporated at the corners. There is also a 33.11% increase in base shear, and the structure's stiffness increases by 6.5 times compared to a soft storey building.

J Sustain Const Mater Technol, Vol. 9, Issue. 4, pp. 355–364, December 2024

Compared to other soft storey mitigation techniques, the seismic performance of soft-storey buildings with shear walls positioned at corners is superior. Future research can assess how well these configurations work together to reduce the soft storey effect in buildings. The most cost-effective way to mitigate the soft storey effect in buildings can also be determined by performing a cost analysis of structures integrated with various strategies.

Ethics

There are no ethical issues with the publication of this manuscript.

Data Availability Statement

The authors confirm that the data that supports the findings of this study are available within the article. Raw data that support the finding of this study are available from the corresponding author, upon reasonable request.

Financial Disclosure

The authors declared that this study has received no financial support.

References

  1. Ahmer, K., & Chouka, S. S. (2020). Seismic perfor- mance evaluation of multi-storey building having (c) soft storey with different location of shear walls. Int J Innov Technol Explor Eng, 9(11), 50-55. [CrossRef]
  2. Sreadha, A. R., Pany, C., & Varkey, M. V. (2020). A review on seismic retrofit of beam-column joints. Int J Mod Trends Sci Technol, 6(9), 80-93. [CrossRef]
  3. Sreadha, A. R., & Pany, C. (2020). Seismic study of multistorey building using floating column. Int J Emerg Sci Eng, 6(9), 6-11. [CrossRef]
  4. Lu, X., Xie, L., Guan, H., Huang, Y., & Lu, X. (2015). A shear wall element for nonlinear seismic analysis of super-tall buildings using OpenSees. Finite Elem Anal Des, 98, 14-25. [CrossRef]
  5. Khudhair, S.Y. (2019) The suitable location for shearing walls on soft storey in high rise buildings to increase its stiffness. Int J Civ Eng Technol, 10(2), Figure 12. Comparison of stiffness for different models in (a) 2096-2105. seismic zone III, (b) seismic zone IV, and (c) seismic zone Vb. [6] Kiran, S., Ramtekkar, G. D., & Titiksh, A. (2017). Comparative study for mitigating the soft storey ef- • Adding a shear wall reduces the soft storey building's fect in multi storey buildings using different struc- tural arrangements. Int J Civ Eng Technol, 8(3), maximum displacement and storey drift by 25.27% and 520-531.
  6. 28%, respectively. The soft storey building's maxi- [7] Dheekshith, K., & Naveen K.M.S. (2018). Compar- mum storey shear rises by 33.38%. ative study on seismic analysis of two RC buildings 364 J Sustain Const Mater Technol, Vol. 9, Issue. 4, pp. 355–364, December 2024 with irregularities under varying seismic zones. Int [14] Takeuchi, T., Wada, A., Matsui, R., Sitler, B., Lin, P., Res J Eng Technol, 5(7), 81-88. Sutcu, F., Sakata, H., & Qu, Z. (2017). Buckling-re-
  7. Gairola, P., & Dhyani, S. (2019). Seismic analysis of strained braces and applications. Japan Society of open soft storey building for different models. Int J Seismic Isolation. Eng Res Technol, 8(5), 124-132. [15] Kannan, S. S. (2023). Seismic analysis of soft storey
  8. Ghate, N.A., & Siddh, S.P. (2018). Seismic demand building in earthquake zones. In IOP Conference Se- of soft storey building and it's strengthening for seis- ries: Earth and Environmental Science (Vol. 1130, mic resistance. Int J Civ Eng Technol, 9(5), 602-610. No. 1, p. 012023). IOP Publishing. [CrossRef]
  9. Shaji, A., Binu, A., Divakaran, D. & Sasidharan, A. [16] Pesaralanka, V., Challagulla, S. P., Vicencio, F., (2019). Seismic analysis of soft storey buildings. Int J Chandra Babu, P. S., Hossain, I., Jameel, M., & Ra- Sci Eng Res, 8(3), 10. makrishna, U. (2023). Influence of a soft story on
  10. Mazza, F., Mazza, M., & Vulcano, A. (2018). the seismic response of non-structural components. Base-isolation systems for the seismic retrofitting of Sustainability, 15(4), 2860. [CrossRef] r.c. framed buildings with soft-storey subjected to [17] Chanumolu, M., & Anthugari, V. (2022). Dynamic near-fault earthquakes. Soil Dyn Earthq Engi, 109, performance of soft-storey structures with gap ele- 209-221. [CrossRef] ments at beam-column joints. Mater Today Proc, 52,
  11. Sharma, P., Rajendra, S., & Vanisree, C. N. (2016) 622-631. [CrossRef] Comparative study on effects of regular and irregu- [18] Qambrani, M. M., Mirza, F., & Habib, M. (2023). lar structures subjected to lateral loading by equiva- Comparative seismic response analysis of a lent static method and response spectrum method. multi-storey building with and without base isola- Int J Adv Eng Manag Sci, 2(5), 263-268. tors under high magnitude earthquake. Eng Proceed,
  12. Halde, V. V., & Deshmukh, A. H. (2015). Review 44(1), 6. [CrossRef] on behavior of soft storey in building. Int Res J Eng [19] Bureau of Indian Standarts. Criteria for earthquake Technol, 2(8), 327-329. resistant design of structures. IS 1893: 2016 Part 1

Share and Cite

K, S.; Praseeda, K.; Pany, A.C. Moderating the Soft Storey Impact in Multi-Storey Buildings A Comparative Seismic Investigation. Journal of Sustainable Construction Materials and Technologies 2024, Vol. 9, pp. 4. https://doi.org/10.47481/jscmt.1607472

Export:

Related Articles

Accelerated alkali-silica reaction after a seven-year ASR-dormancy periodAhsanollah Beglarigale, 1 January 2024Accelerated microwave curing of hybrid geopolymers with nano-silica for enhanced physico-mechanical propertiesBolat Balapanov, Sarsenbek Montayev et al., 1 January 2024Clustering Analysis of Compressive Strength of Structural Recycled Aggregate ConcreteHasan Dilbas and Mehmet Şamil Güneş, 1 January 2024Effect of sealed water curing and fiber length on compressive strength and fracture energy of fly ash-based geopolymer mortarsAdil Gültekin, 1 January 2024
Publication History
Published1 January 2024
Versionv1
AccessOpen Access
10.47481/jscmt.1607472
Article Figures (9)
Figure 1Figure 2Figure 3Figure 4Figure 5Figure 6Figure 7Figure 8Figure 9
Related Articles
Accelerated alkali-silica reaction after a seven-year ASR-dormancy periodAhsanollah BeglarigaleJournal of Sustainable Construction Materials and Technologies, 1 January 2024Accelerated microwave curing of hybrid geopolymers with nano-silica for enhanced physico-mechanical propertiesBolat Balapanov, Sarsenbek Montayev et al.Journal of Sustainable Construction Materials and Technologies, 1 January 2024Clustering Analysis of Compressive Strength of Structural Recycled Aggregate ConcreteHasan Dilbas and Mehmet Şamil GüneşJournal of Sustainable Construction Materials and Technologies, 1 January 2024
Journal of Sustainable Construction Materials and Technologies coverJournal of Sustainable Construction Materials and Technologies Download PDF

Subscribe to YTUP

Stay connected and receive the latest research updates directly in your inbox.

YTUP — Yıldız Technical University Publishing

Advancing knowledge and fostering innovation through high-quality, peer-reviewed academic publications.

About YTU

Discover

  • ›Articles
  • ›Journals
  • ›Research Topics
  • ›Open Access Policy

Guidelines

  • ›Author guidelines
  • ›Services for authors
  • ›Policies and publication ethics
  • ›Editor guidelines
  • ›Fee policy

Explore

  • ›Articles
  • ›Research Topics
  • ›Journals
  • ›How we publish

Support

  • ›Help center
  • ›Emails and alerts
  • ›Contact us
  • ›Submit
  • ›Career opportunities
YTU Logo

© 2026 Yıldız Technical University (Istanbul, Turkey)

Terms and ConditionsTerms of UsePrivacy PolicyPrivacy SettingsDisclaimer
Like this platform? Join our teamHave feedback or questions?
Supervisor